• About Us
  • Reach Us
  • Amber Media LLP
  • Sign Up
  • member login
Your Gateway to Power Transmission & Distribution
  • Home
  • News
    • T&D News
    • Power Equipment
    • Power Distribution
    • International News
    • New Products
    • Orders & Contracts
    • Renewables
    • New Appointments
    • In Brief
    • Awards & Accolades
    • E-mobility
  • Interview
  • Special Report
    • Special Stories
    • Special Story
  • By Invitation
  • Events
  • Monthly Issues
  • Sign In
    • Login
    • Sign Up
  • T&D News

GameChange BOS transformers achieve short-circuit certification from CPRI

  • T&D India
  • March 3, 2026
Share

GameChange BOS, the transformer division of GameChange Energy Technologies, has announced its successful completion of dynamic short circuit type testing for its high-capacity, multi-winding transformers.

The rigorous type test, conducted at the Central Power Research Institute (CPRI) in Bhopal, Madhya Pradesh, validates the company’s manufacturing readiness to supply grid-compliant, resilient transformers for renewable energy and utility applications worldwide, a release by GameChange BOS said.

 

The destructive short-circuit test assesses a transformer’s ability to withstand dynamic mechanical impacts due to short circuits, and extreme electrical conditions that can occur during grid disturbances.

 

GameChange BOS’s 17.6 MVA, 5-winding inverter duty transformer (IDT) successfully endured nine consecutive asymmetrical shots at 100 per cent of requested current for 0.25 seconds each—confirming its resilience against the types of severe electrical events that can cause catastrophic equipment failure.

 

 

Conducted in accordance with International Electrotechnical Commission (IEC) standards, the comprehensive testing program included:

  • Routine measurements per IEC 60076-1, performed both before and after short-circuit tests to verify electrical performance integrity
  • Short-circuit tests per IEC 60076-5, utilizing a three-phase supply on the high-voltage (HV) side with pre-set short-circuit on the low-voltage (LV) side
  • Dielectric routine testing per IEC 60076-3, including Applied Voltage (AV) and Induced Voltage Withstand (IVW) tests conducted before and after short-circuit events
  • Sound level determination in no-load conditions per IEC 60076-10
  • Physical inspection following complete transformer un-tanking to visually examine internal active parts, in compliance with IEC 60076-5 Clause 4.2.7.4-a

 

From 138kV to 345kV

With capacity for transformers up to 138kV and 50 MVA (with planned expansion to 345kV and 300 MVA), the company provides fast delivery timelines at a time when traditional transformer lead times remain extended. The company has already surpassed 190 medium-voltage transformer orders, with strong demand driven by renewable energy project timelines, Safe Harbor qualification requirements, and customers seeking to mitigate Foreign Entity of Concern (FEOC) supply chain risks.

 

Proven reliability

“This certification represents a significant milestone in proving our transformers’ reliability under the most demanding real-world conditions,” said Phillip Vyhanek, CEO of GameChange BOS. “This testing validates that GameChange BOS transformers are built to perform when it matters most for our clients.”

Also read: GameChange Energy Technologies acquires Terrasmart’s eBOS division

Featured photograph showing CPRI’s testing facility at Bhopal is for representation only (Photo: CPRI)

 

Tags
  • CPRI
  • dynamic short circuit test
  • GameChange BOS
  • inverter duty transformer
  • Share this post
  • twitter
  • pinterest
  • facebook
  • google+
  • email
  • rss
Epsilon Composite supporting the India–France strategic collaboration on critical infrastructure
GE Vernova to expand transformer bushings capacity in Italian plant

Leave a Comment Cancel reply

Your email address will not be published. Required fields are marked *

Subscribe to our Newsletter

Recent Posts
  • Siemens expands semiconductor-based circuit protection portfolio, introduces circular soft starter
  • Genus Power crosses 26-million smart meter deployment worldwide
  • Bidders shortlisted for Jalna intrastate-TBCB scheme in Maharashtra
  • PGCIL set to fully commission Kurnool RE evacuation scheme soon
  • Apraava Energy commissions Fatehgarh IV interstate-TBCB scheme in Rajasthan
Your Gateway to Power Transmission & Distribution

We invite you to consider sustained advertisement campaigns in “T&D India” We assure you of unmatched exposure at very cost-effective rates. for more details please mail us at info@tndindia.com

  • About Us
  • Amber Media LLP
  • Sitemap
  • IndiaPowerFactor
  • Contact Us
© 2016-2025 All rights reserved | Site Owned by Amber Media.